| |AC Servo Drives|PLCs| |
| PROGRAMMABLE LOGIC CONTROLLERS(PLC) |
| |
 |
| |
| DVP02LC-SL |
- Number of group controlled: 2
- 24-bit high resolution
- Application for 4-or 6 - wire load cell
- Resolution and reaction speed adjustable
- Accurate and stable tension control
- Software developed for actual needs
- For remote independent RS – 485 load cell application
|
| |
|
|
|
| |
| DVP-10PM |
- MPU points:24I/O point 256

- Program capacity 64k step
- Built in hardware digital filter for counting
- 6 High speed counters (O.C 200 kHz * 4, differential 200 kHz * 2) supporting
U/D, U/D Dir. A/B 4A/B Counting mode
- 4 differential 1mhz outputs supporting U/D,U/D Dir, A/B output modes
- Support 1- speed (immediate stop after the marks arrives), 2-speed, Zero return, MPG and single axis function
- Highly accurate PWM 200 KHz out resolution 0.3%
- Electronic Gear function
- 8 high speed captures (mark correction frequency measurement) comparative output, mark, mask function (for bag making)
- 8 external interruptions for setting up rising – and falling edge triggers, 1 timed interruption
- High efficient command execution. LD 0.1375us, MOV 2.1us
|
| |
|
|
|
| |
| DVP – 20PM |
- MPU points 16
- Max I/O points 512
- Program Capacity 64 K steps
- Built in RS – 232 and RS -485 Ports, Compatibility with Modbus ASCII/RTU protocol
- Data register 10k words
- File register 10 k words
- Max. Pulse output 500 kHz
- Compatible with G-code/M-code
- Built in 2A/B phase differential signal output
- Supports MPG input
- 3-axis linear/arc/helical interpolation
- Support electronics cam (2,048 point) and flying shear application
|
| |
|
|
|
| |
| DVP-EH2 |
- MPU points 16/20/32/40/48/64/80
- Max. I/O points 512
- Program capacity 16k steps
- Program execution speed 0.24us (basic instruction)
- Built in RS 232 and RS 485 ports compatible with Modbus ACSII/RTU protocol
- Data Register 10kwords
- File register 10k words
- High speed pulse output 20-and 32 point models support 2 point (y0, y2) of 200 kHz Pulse output 40 point models support 4 point (y0, y2, y4, y6) of 200 kHz pulse output
- Support max 4 hardware 200 kHz high speed counter
- DVP32EH2-L model support left side speed module extension
|
| |
|
|
|
| |
| DVP- SV |
- MPU points 28
- Max. I/O point 512
- Program capacity 16k steps
- Program execution speed 0.24 us(basic instruction)
- Built in RS 232 and 485 ports, compatible with Modbus ASCII/RTU protocol
- Data register 10k words
- File register 10k words
- High speed pulse output support 4 point (y0,y2,y4,y6) of 200khz pulse output
- Built in 4 hardware 200khz high speed counters
|
| |
|
|
|
| |
| DVP – SS2 |
- MPU points 14
- Max. I/O point 480
- Program capacity 8k steps Device D: 5k words Compatible with program of the existing DVP-SS Series PLC
- Program execution speed 0.35 to 1us (basic instruction),3.4us(MOV)
- High speed pulse output 4 point of 10khz pulse output
- Max. 8 point of high speed input and external interruption input(20khz*4point,10khz*4 point)
- Built in RS 232 and RS 485 ports compatible with Modbus ASII/RTU protocol can be master or slave
|
| |
|
|
|
| |
| DVP-SA2 |
- MPU point 12
- Max. I/O point 480 (left side extendable to high speed modules)
- Program capacity 8k steps Device D 10k words Compatible with program of the existing DVP-SA series PLC
- Program execution speed 0.35 to 1us (basic instruction), 3.4us (MOV)
- High speed pulse output 4 point of pulse output (100khz*2,1010khz*2)
- 8 point of high speed pulse input and external interruption input (100 kHz*3point, 10 kHz * 5 point, 1A/B phase input can reach 50khz)
- Built in 1RS 232 and 2RS – 485 ports compatible with Modbus ASCII/RTU protocol can be master or slave.
|
| |
|
|
|
| |
| DVP-SX2 |
- MPU point 20
- Max. I/O point 480 (left side extendable to high speed modules)
- Program Capacity 16k steps Device D 10k words Compatible with program of the existing DVP-SX series PLC
- Program execution speed 0.35 to 1us (basic instruction), 3.4us (MOV)
- Built in mini USB for program upload /download and monitoring
- 4 point of high speed pulse output (100khz*2,10khz*2)
- 8 point of high speed pulse input and external interruption input(100khz*2,10khz*6)
- Built in RS – 232 and RS 485 ports compatible with Modbus ASCII/RTU protocol can be master or slave.
|
| |
|
|
|
| |
| DVP-ES2/EX2 |
- MPU point 16/20/24/32/40/60
- Max. I/O point 256
- Program capacity 16k steps
- Program Execution speed 0.54us
- Built in 1 RS 232 and 2 RS 485 Ports compatible with Modbus ASCII/RTU protocol can be master or slave
- Data register 10 k words
- Built in 8 point high speed input (100khz*2,10khz*6)supporting U/D, U/D Dir. CW/CCW, A/B counting modes
- Built in 4 point of pulse input (100 kHz * 2, 10 kHz * 2) supporting pulse, pulse Dir. A/B , CW,CCW modes
|
| |
|
|
|
| |
| DVP-ES /EX |
- MPU point ES 14/24/30/32/40/60EX: 20
- Max. I/O point 256 (ES) , 238(EX)
- Program capacity 4k steps
- Built in RS 232 and RS 485 Ports compatible with Modbus ASCII/RTU protocol
- 2 point (y0, y2) of 10 kHz pulse output
- Built in 4 point of high speed counters
|
| |
|
|
|
| |
| DVP-SS |
- MPU point 14
- Max. I/O point 238
- Program capacity 4k steps
- Built in RS – 232 and RS 485 Ports compatible with Modbus ASII/RTU protocol
- 2 point (y0.y1) of 10 kHz speed counters
- Built in 4 point of high speed counters
|
| |
|
|
|
| |
| DVP-SA |
- MPU point 12
- Max. I/O point 236
- Program capacity 8k steps
- Built in RS – 232 and RS 485 Ports compatible with Modbus ASII/RTU protocol
- 1 point (y0) of 50 kHz speed and 1 point (y1) of 10khz pulse output
- Built in 6 point of high speed counters
|
| |
|
|
|
| |
| DVP-SX |
- MPU point 10
- Max. I/O point 230
- Program capacity 8k steps
- Built in RS – 232 and RS 485 Ports compatible with Modbus ASII/RTU protocol
- 1 point (y0) of 50 kHz speed and 1 point (y1) of 10kHz pulse output
- Built in 4 point of high speed counters
|
| |
|
|
| |
| |
| DVP-SC |
- MPU point 12
- Max. I/O point 236
- Program capacity 8k steps
- Built in RS 232 and RS – 485 ports compatible with Modbus ASCII/RTU protocol
- 2 point (y10,y11) of 100 kHz pulse output
- Built in 2 point of 100khz high speed counter
|